The width of stairs in a residential building should be at least
The width of stairs in a residential building should be at least
Ui is not developed when?
Ui is not developed when?
When a structural member of the uniform section is subjected to a moment at one end only, then the moment required so as to rotate that end to produce a unit slope, is called _____
When a structural member of the uniform section is subjected to a moment at one end only, then the moment required so as to rotate that end to produce a unit slope, is called _____
In the working stress method of R.C.C. design factor of safety used for concrete and steel are respectively
In the working stress method of R.C.C. design factor of safety used for concrete and steel are respectively
If in an interior beam, adjacent structures are exactly similar then the tributary area is:-
If in an interior beam, adjacent structures are exactly similar then the tributary area is:-
Force-displacement requirement of statically indeterminate structures depend upon which factor?
Force-displacement requirement of statically indeterminate structures depend upon which factor?
For a cantilevered beam, where would absolute maximum shear occur?
For a cantilevered beam, where would absolute maximum shear occur?
In cantilever retaining walls
In cantilever retaining walls
For a cantilevered beam, where would absolute maximum moment occur?
For a cantilevered beam, where would absolute maximum moment occur?
The shape of the cable, when loaded with uniformly distributed load throughout the span is _____
The shape of the cable, when loaded with uniformly distributed load throughout the span is _____
Which of the following is carried by truss members?
Which of the following is carried by truss members?
If in an interior beam, adjacent structures are exactly similar then the tributary area is:-
If in an interior beam, adjacent structures are exactly similar then the tributary area is:-
A pin-jointed plane frame is unstable if
A pin-jointed plane frame is unstable if
In case of a beam, resistance to normal force is considered to be more important than resistance to bending and shear force.
State whether the above statement is true or false.
In case of a beam, resistance to normal force is considered to be more important than resistance to bending and shear force.
State whether the above statement is true or false.
In the equation U-0.9D + 1.6W + 1.6H, what is the load factor for H if the structural action of H counteracts that due to W or E?
In the equation U-0.9D + 1.6W + 1.6H, what is the load factor for H if the structural action of H counteracts that due to W or E?
Which of the following is false for deflection of a point nearby a fixed support?
Which of the following is false for deflection of a point nearby a fixed support?
The maximum spacing of vertical shear reinforcement for a beam of size 250 x 360 mm is
The maximum spacing of vertical shear reinforcement for a beam of size 250 x 360 mm is
If a structure has 2j – r no. of members, then it will be:-
If a structure has 2j – r no. of members, then it will be:-
Load transfer to girders happen at only some points. What are they called?
Load transfer to girders happen at only some points. What are they called?
If a structure has total 10 joints, then what should be the minimum no. of joints in which equilibrium equations should be concurrently satisfied for stability?
If a structure has total 10 joints, then what should be the minimum no. of joints in which equilibrium equations should be concurrently satisfied for stability?
If we use link support in a structural system, then how many unknowns would we have
If we use link support in a structural system, then how many unknowns would we have
Generally, which parts’ ILD is given the most preference?
Generally, which parts’ ILD is given the most preference?
Characteristic load means
Characteristic load means
Floor loads are transmitted from slabs to which part in a floor girder system?
Floor loads are transmitted from slabs to which part in a floor girder system?
In the case of a structural member supporting more than one floor with load exceeding 100psf., what is the maximum permitted reduction %?
In the case of a structural member supporting more than one floor with load exceeding 100psf., what is the maximum permitted reduction %?